• Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
  • Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
  • Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
  • Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
  • Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
  • Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB

Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: ACB

Contact Supplier

Diamond Member Since 2008

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZW7-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, CB, CCC
Rated Voltage
40.5kv
Rated Current
1250/1600/2000A
Rated Frequency
50/60Hz
Model Number
3 Poles
Mechanism
Central Operating Mechansim
Transport Package
Non-Solid Wooden Case for Export Shipment
Specification
IEC: M2-E2-C2
Trademark
Longxiang Electric
Origin
Baoji, Shaanxi China
HS Code
85389000
Production Capacity
16000sets/Year

Product Description

ZW7-40.5 Outdoor Voltage Vacuum Circuit Breaker With Central Operating Mechanism

General Description
ZW7-40.5 series of outdoor High Voltage Vacuum Circuit Breaker With Central Operating Mechanism are three phase,A.C 50(60) Hz 
outdoor high voltage distribution equipment with 40.5kV rated voltage ,which can be used to open or close loading current,
over-loading current and short-circuit current, it is widely used in rural electrical network and comply with GB1984-2003 standard.


The overall structure of this product adopt porcelain insulator support type,the vacuum interrupter is installed inside the upper insulator,
the lower insulator is used for support bottle,three phases are amounted on the same mechanism box,the moving end of vacuum interrupter
is connected with operating mechanism through shaft and insulation lever.The operation is easy and convenient.


Applying ambient conditions
1.Ambient temperature:-30ºC~+40ºC
2.Ambient humidity:the average humidity of a day should be no more than 95%:the average humidity of a month should be no more than 90%.
3.Earthquake intensity:not exceed 8degrees.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa:the average pressure of a month should be no more than 1.8kPa.
5.The height above sea level:≤1000m.
6.Air filthy degree: III degrees.

7.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.

Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB



Our Factory

Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB



Packaging & Delivery.
Packaging Details Non-solid wooden case(Stand export package).
Delivery Detail Within 10~15days from the date of receiving signed sales confirmation by both parties.

Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB

Welcome for enquiry and factory visit!

Send your message to this supplier

*From:
*To:
avatar Mr. Lee
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now