• VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
  • VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
  • VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
  • VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
  • VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
  • VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch

VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch

Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Withdrawable & Fixed
Structure: ACB
Manufacturer/Factory & Trading Company
Diamond Member Since 2008

Suppliers with verified business licenses

Shaanxi, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (28)

Basic Info.

Model NO.
VIB-12/1250-31.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection
Certification
VDE, ISO9001-2000, CE, CB, CCC
Rated Voltage
12kv
Rated Frequency
AC 50Hz
Industry Standard
M2-E2-C2
Transport Package
Each One Is Wrapped with Plastic Film in Cartons.
Specification
IEC: M2-E2-C2
Trademark
Longxiang Electric
Origin
Baoji, Shaanxi China
HS Code
85389000
Production Capacity
16000sets/Year

Product Description

VIB-12 Indoor High Voltage Vacuum Circuit Breaker

General Description
Explation of Product type: VIB  -     12

Vacuum Circuit Breaker series        Rated voltage(kV)
of Longxiang Electrical Co.,Ltd.


Main usage,applying ambient conditions
VIB type indoor high voltage vacuum circuit breaker(Hereinafter referred to as vacuum circuit breaker)are used for 12kv rated voltage  and AC 50Hz indoor switch equipment components.The products meet standard of GB1984-2003HV AC Vacuum Circuit Breaker,
JB3855-1996 3.6~40.5kV Indoor AC High Votage Vacuum Circuit Breaker, DL/T403-2000 Order Technical Condition of 12kV~40.5kV
Vacuum Circuit Breaker and IEC62271-100:2001HV AC Vacuum Circuit Breaker,etc.

Circuit breaker used as protection and control unit of power design in electric network and industrial and minning enterprises, can be used for situation of switching various types of load and frequent operation and repeated breaking shor circuit current.


This type VCB uses new type operating mechanism of VCB.Embed vacuum interrupter and main circuit's components as a integration  by adopting embedded pole of international brand for primary part,so as to protect vacuum interrupter from crash,dust and moist. It has good environment adaptability, so that reducing operation and maintenance cost greatly and realizing maintenance free of primary part  and few maintenance of operating mechanism. The integrated design of operating mechanism and VCB body has passed type test. It has E2 level electrical endurance and M2 level mechanical endurance,used as fixed unit and also withdrawable unit by matching specialized
push-in mechanism.The fixed type VCB can add corresponding interlock for matching fixed type switchgear of XGN2,GG1A and GGX type.



Applying ambient conditions
1.Ambient temperature:Max. Temperature:40ºC,and average temperature within 24h should no more than35ºC  
2.Relative humidity:The average relative humidity daily:≤95%
                               The average relative humidity monthly:≤90%
                               The average vapour pressure daily:≤2.2kPa
                               The average vapour pressure monthly:≤1.8kPa
3.The height above sea level:≤2000m

4.Earthquake intensity:not exceed 8 degrees.
5.It should be installed in the place without fire,chemical erosion,explosion,vapour and salt spray.

Technical parameter
S.N Name Unit Data
1 Rated voltage kV 12
2 Rated frequency Hz 50
3 1min power frequency withstand voltage kV 42
4 Rated lighting impulse withstand voltage kV 75
5 Rated current A 630 1250 1600 2000 2500 3150 4000
6 Rated short circuit breaking current
Rated thermal stability current(virtual value)
kA 20            
25 25          
31.5 31.5 31.5 31.5 31.5    
  40 40 40 40 40 40
            50
7
 
Rated short circuit making current(peak)
Rated dynamic stable current(peak)
kA 50            
63 63          
80 80 80 80 80    
  100 100 100 100 100 100
            125
8 Switching operations of short circuit breaking current Cycle 30,50
9 Rated thermal stable duration s 4
10 Rated operating sequence   O-0.3s-CO-180s-CO
11 Mechanical endurance Cycle 30000
12 Rated breaking current of single capacitor bank  A 630
13 Rated breaking current of back to back capacitor bank A 400


Outline drawing and installation dimension
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch

Our Factory

VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
Our Certificates

VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker Switch
VIB-12 AC 50Hz Indoor High Voltage Vacuum Circuit Breaker SwitchWelcome for enquiry and factory visit!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now