Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: ACB
Manufacturer/Factory & Trading Company
Diamond Member Since 2008

Suppliers with verified business licenses

Shaanxi, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (28)

Basic Info.

Model NO.
ZN28-12K
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection
Certification
VDE, ISO9001-2000, CE, CB, CCC
Rated Voltage
12kv
Rated Current
630/1250/1600/2000/2500/3150A
Rated Frequency
50/60Hz
Transport Package
Non-Solid Wooden Case for Export Shipment
Specification
IEC: M2-E2-C2
Trademark
Longxiang Electric
Origin
Baoji, Shaanxi China
HS Code
85389000
Production Capacity
16000sets/Year

Product Description

ZN28-12K Fixed Type of Indoor High Voltage Vacuum Circuit Breaker

General Description
 ZN28-12K fixed type indoor HV vacuum breaker is used for many kinds of switchgear like XGN2-12(Z).   It is widely used for 12kV voltage systems which is accordance with GB1984-2003 standards Structural characteristics:
1.This vacuum circuit breaker adopts air insulation ,it can meet air distance and creepage under nomal run condition.
2.The operating mechanism can use CD17or CT19 type mechanism,the outlet curve has good adaptation for the requirements 
  of vacuum interrupters. It has high reliable with characteristic of long life and easy maintenance.

3.Convenient for matching with switchgear;convenient and reliable operation:compulsive mechanical interlock way is adopted:
   meet the 
"Five Preventions"function.
 
 Applying ambient conditions
1.Ambient temperature:-15~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
4.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa:the  average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire,explosion,serious filth, chemical erosion and violent vibration.

  Main Technical Specification
S.N Name Unit Data
1 Rated voltage kV 12
2 Rated frequency Hz 50/60
3 Rated current A 630 630   1250   1600
1000 1000 1600 2000
1250 1250 2000 2500
      3150
4 Rated short circuit breaking current    kA   20    25    31.5    40
5 Rated peak withstand current    kA   50    63     80    100
6 Rated short-circuit duration     s                             4
7 Rated power frequency withstand voltage Between phases,
phase to  ground
   kV                            42
Between gaps    kV                            48
8 Rated lightning impulse withstand voltage Between phases,
phase to ground
   kV                             75
Between gaps    kV                             85
9 Rated operating sequence   O-0.3s-CO-180s-CO
O-180s-CO-180s-CO(40kA)
10 Rated source voltage of opening and closing circuit    V ~220/-110;-220/110
11 Rated breaking current of single capacitor bank    A                            630
12 Rated breaking current of bank to bank capacitor bank    A                            400
13 Electrical endurance class Cycle                              30
14 Mechanical endurance Cycle                           10000
15 Operating mechanism type   CD17I CD17II CD17II CD17III
CT19I CT19I CT19I CT19II
16 Clearance between open contacts mm 11±1
17 Contact stroke of contacts   mm 4±1
18 Out simultaneity of CO operation of three poles   ms ≤2
19 Contact bouncing duration at closing operation   ms ≤2
20 Closing time    ms 50~100
21 Opening time    ms 20~60
22 Average closing speed    m/s 0.6±0.2
23 Average opening speed    m/s 1.1±0.2
24 Main circuit resistance of each pole    μΩ ≤40 ≤40    ≤40    ≤30
25 DC component                         50%(Max.)

  Overall outline drawing
ZN28-12K Fixed Type of Indoor High Voltage Vacuum Circuit Breaker
 
ZN28-12K Fixed Type of Indoor High Voltage Vacuum Circuit Breaker
 
ZN28-12K Fixed Type of Indoor High Voltage Vacuum Circuit Breaker
Welcome for inquiry and factory visit!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now